Sample Turret in TIMS [IOMS]

Main
Glossary

WHAT IT IS

The sample turret is a mechanical component within TIMS instruments that holds several sample filaments at once. Each filament contains a sample to be analyzed. The turret rotates to sequentially position each filament into the ionization source, where samples are heated for ionization. Turrets in modern TIMS typically hold about 20-21 filaments, depending on the instrument design, allowing multiple samples to be analyzed without manual intervention.

HOW IT WORKS

Sample Loading: Multiple sample filaments are mounted onto the turret before analysis.

Turret Rotation: The turret rotates to move each sample filament into the ionization source one at a time.

Ionization Process: Each filament is heated to release ions from the sample, which are then analyzed by the mass spectrometer.

Automated Operation: The turret is controlled by software, enabling automated sample introduction and reducing the need for manual handling during long analysis runs.

IMPACT ON PERFORMANCE

Increased Throughput: The ability to load multiple samples simultaneously allows continuous operation, reducing downtime between analyses.

Improved Efficiency: Automated sample positioning minimizes manual intervention, saving time and labor.

Enhanced Reproducibility: Consistent sample positioning ensures reliable and reproducible results across multiple analyses.

Flexibility in Sample Handling: Supports a variety of sample types and sizes, enhancing the versatility of the TIMS instrument.

ADVANTAGES 

Automated Sample Introduction: Reduces manual handling, improving efficiency and minimizing human error.

Higher Sample Capacity: Holds multiple samples, allowing extended analysis without user intervention.

Consistent Positioning: Ensures that each sample is introduced in the same way, enhancing analytical reproducibility.

Time-Saving Operation: Facilitates back-to-back sample analysis, increasing the overall throughput of the instrument.

CHALLENGES AND LIMITATIONS

Mechanical Complexity: Turrets require precise mechanical design and regular maintenance to ensure accurate rotation and positioning.

Limited Sample Capacity: The number of samples is restricted by the turret size, which may limit throughput in high-volume labs.

Potential for Contamination: Improper handling during sample loading can lead to cross-contamination between samples.

Maintenance Needs: Regular calibration and cleaning are necessary to maintain turret performance and prevent mechanical wear.