Specifications

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Glow Discharge Mass Spectrometry
  • Manufacturer: Thermo Fisher Scientific
  • Country: Germany
  • Available: Active
All specifications

About

Short description

High-resolution glow discharge mass spectrometer (GD-MS) tailored for the direct analysis of solid materials. Features exceptional sensitivity, ultra-low detection limits, and minimal matrix effects for routine and research applications.

Specifications

High-resolution glow discharge mass spectrometer (GD-MS) tailored for the direct analysis of solid materials. Features exceptional sensitivity, ultra-low detection limits, and minimal matrix effects for routine and research applications.

  • Status: Active
  • Country: Germany
  • Isotopic: Yes
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Isotopes of metals, semiconductors, and trace impurities
  • Analyzer type : Magnetic Sector MS
  • Ion source type: Glow discharge
  • Inlet types: Flat and pin sample holders for solid samples
  • Mass range : 3-260 amu
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Adjustable resolutions: R≥300, R≥4000, R≥10,000
  • Sensitivity : >1×10¹⁰ cps (total ion current) for copper in medium resolution
  • Dynamic range : 12 orders of magnitude
  • Detection limits : Sub-ppb level detection
  • Precision : High precision: ±2% for isotopic ratio measurements
  • Signal stability, relative standard deviation : <3% for major components over extended operation
  • Detector type : Faraday cup and secondary electron multiplier (SEM)
  • Acceleration voltage : 8 kV
  • Discharge parameters : Voltage: 500–1400 V; Current: 5–75 mA; Gas flow: 300–500 mL/min
  • Geometry type : Reverse Nier-Johnson sector geometry
  • Focusing type : Ion beam focusing with fixed-slit design
  • Magnetic sector radius/ angle : 160 mm/ 60 deg
  • Electric sector radius/ angle : 105 mm/ 90 deg
  • Cooling system : Water cooling
  • Vacuum system : Oil-free system with high-capacity turbo molecular pumps
  • Gas supply: Argon 5.0 or higher (purge and discharge gases)
  • Power Requirements and Consumption : 3-phase 230/400 V, 50/60 Hz; 8 kVA consumption
  • Environmental requirements : Temperature: 18–24°C; Humidity: 50–60%
  • Dimensions and Weight: Width: 1720 mm; Depth: 880 mm; Height: 1410 mm; Weight: 723 kg

Articles

Other company product

Talos F200S

  • Category: Electron Microscopy
  • Technique: Transmission Electron Microscopy
  • Manufacturer: Thermo Fisher Scientific
  • Country: USA
  • Available: Active
Detailed