Home
About
Articles
Instrument Database
Laboratory Finder
Service Provider Finder
Consumables Supplier Finder
Method Developing and Training Finder
Glossary of Terms
Partnership
Contacts
Partnership
Contacts
Log in
About
Articles
Laboratory Finder
Service Provider Finder
Consumables Supplier Finder
Method Developing and Training Finder
Glossary of Terms
Inst. Database
Instruments
Cookies
We respect your privacy and are committed to protecting your personal information.
Here's how we handle your data: No tracking cookies. We do not use cookies or similar technologies to track your ...
Privacy policy
OK
isoprime precisION
Main
Inst. Database
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Specifications
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Elementar
Country:
Germany
Available:
Active
All specifications
Download “Conclusions.PDF”
Download “Conclusions.PDF”
About
Specifications
About
Short description
Compact benchtop design stable isotope ratio mass spectrometer.
All about
Specifications
Compact benchtop design stable isotope ratio mass spectrometer.
Status:
Active
Country:
Germany
Isotopic:
Yes
Type of measurable elements:
Light stable isotopes (C, N, S, O, H)
Measurable isotopes/elements:
¹³C/¹²C, ¹⁵N/¹⁴N, ¹⁸O/¹⁶O, ³⁴S/³²S, ²H/¹H
Analyzer type
:
Magnetic Sector MS
Ion source type:
Electron impact
Inlet types:
Continuous flow (centrION), dual inlet, and various custom inlet systems
Mass range
:
1–96 Dalton
Mass resolution/ Mass resolving power
:
Greater than 110 m/Δm (10% valley separation)
Multicollector
:
Yes
Collectors qty
:
Simultaneous measurement of up to 10 ion beams with flexible collector configurations
Sensitivity
:
Continuous flow: 1,100 molecules CO₂/ion; Dual inlet: 800 molecules CO₂/ion
Abundance sensitivity
:
≤8.0 ppm/nA H₃⁺ correction factor
Detection limits
:
Sub-ppm levels
Precision
:
±0.06‰ for 13C and 15N; ±0.2‰ for 2H
Detector type
:
Faraday collectors
Possible amplifiers
:
100 V dynamic range with auto-resistor switching
Acceleration voltage
:
5 kV
H3 Factor
:
≤8.0 ppm/nA
Geometry type
:
90° stigmatic focusing magnetic sector
Focusing type
:
Single focusing
Magnetic sector radius/ angle
:
108 mm
Cooling system
:
Air-cooled system
Vacuum system
:
Single turbomolecular pump with stainless steel construction for high vacuum performance
Gas supply:
Helium, oxygen, and other gases based on application requirements
Power Requirements and Consumption
:
110–240 V, 50–60 Hz; 8.0–4.3 A
Environmental requirements
:
Temperature: 18–25°C; Humidity: ≤60%
Dimensions and Weight:
59.5 cm (W) x 46 cm (D) x 65 cm (H); Weight: 102 kg
Articles
Create an Account
Add to favorites and compare instrument, labs, articles, etc.
Proceed
Other company product
isoprime precisION
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Elementar
Country:
Germany
Available:
Active
Detailed
Related equipment
Ultra 271
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Active
Detailed
Horizon 2
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Nu Instruments
Country:
UK
Available:
Active
Detailed
IDMicro EA
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Compact Science Systems
Country:
UK
Available:
Active
Detailed
Delta Q
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Active
Detailed
SIRIX
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Isotopx
Country:
UK
Available:
Active
Detailed
Delta Advantage
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Discontinued
Detailed
Isolab
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Compact Science Systems
Country:
UK
Available:
Active
Detailed
isoprime precisION
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Elementar
Country:
Germany
Available:
Active
Detailed
253 Plus 10kV
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Active
Detailed
Orbitrap Exploris™ Isotope Solutions
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Active
Detailed
HS2022
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Sercon
Country:
UK
Available:
Active
Detailed
Integra2
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Sercon
Country:
UK
Available:
Active
Detailed
Panorama
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Nu Instruments
Country:
UK
Available:
Active
Detailed
isoprime visION
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Elementar
Country:
Germany
Available:
Active
Detailed
Delta V
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Discontinued
Detailed
Isologger
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Compact Science Systems
Country:
UK
Available:
Active
Detailed
Perspective
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Nu Instruments
Country:
UK
Available:
Active
Detailed
Ultra
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Thermo Fisher Scientific
Country:
Germany
Available:
Discontinued
Detailed
IDMicro Breath
Category:
Inorganic and Isotopic Mass Spectrometry
Technique:
Isotope Ratio Mass Spectrometry for Light Stable Isotopes
Manufacturer:
Compact Science Systems
Country:
UK
Available:
Active
Detailed