Specifications

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Secondary Ion Mass Spectrometry
  • Manufacturer: Compact Science Systems
  • Country: France
  • Available: Active
All specifications

About

Short description

High-resolution SIMS instrument for isotopic and elemental analysis with sub-micron resolution. Supports multi-element analysis and 3D mapping. Equipped with advanced primary ion sources and multicollection.

Specifications

High-resolution SIMS instrument for isotopic and elemental analysis with sub-micron resolution. Supports multi-element analysis and 3D mapping. Equipped with advanced primary ion sources and multicollection.

  • Status: Active
  • Country: France
  • Isotopic: Yes
  • Elemental: Yes
  • Type of measurable elements: Most of elements, isotopes, and molecular species
  • Measurable isotopes/elements: Most isotopes from H to Pu, optimized for light and heavy isotopes
  • Analyzer type : Magnetic Sector MS
  • Ion source type: Cs+ and O- (RF-plasma or duoplasmatron)
  • Inlet types: Solid samples with standard holders
  • Mass range : given by the factor D = X 22 between minimum mass and maximum mass (ex: from 1 amu to 22 amu or from 10 amu to 220 amu depending on the selected B-field in the electro- magnet
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Up to 7500 (depending on slit size and configuration)
  • Multicollector : Yes
  • Collectors qty : 5 (NanoSIMS 50), 7 (NanoSIMS 50L)
  • Sensitivity : High sensitivity with ion detection limits in sub-ppm levels
  • Detection limits : Sub-ppm for specific isotopes under optimized conditions
  • Detector type : Electron multipliers and Faraday cups
  • Primary beam : Cs+ or O- with high brightness and adjustable energy
  • Voltage : +8 kV (Cs+), -8 kV (O-)
  • Spatial resolution : ≤ 50 nm (Cs+), ≤ 200 nm (O-)
  • Depth profile : Depth resolution of 10-20 nm per decade
  • Beam energy : 16 keV (Cs+, O-)
  • Camera : Integrated high-resolution imaging for navigation
  • Geometry type : Coaxial, optimized for secondary ion collection
  • Focusing type : Achromatic focusing for enhanced transmission
  • Magnetic sector radius/ angle : 145-680 mm/ 90 deg
  • Electric sector radius/ angle : 100 mm/ 90 deg
  • Cooling system : Water cooling for sources and detectors
  • Vacuum system : Turbo-molecular and ion pumps
  • Gas supply: Standard gas delivery systems for Cs and O2

Articles

Other company product

Isolab

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Isotope Ratio Mass Spectrometry for Light Stable Isotopes
  • Manufacturer: Compact Science Systems
  • Country: UK
  • Available: Active
Detailed