Specifications

  • Category: Spectroscopy
  • Technique: Atomic Absorption Spectroscopy
  • Manufacturer: PerkinElmer
  • Country: USA
  • Available: Active
All specifications

About

Short description

Combines Flame and Transversely Heated Graphite Furnace (THGA) capabilities for exceptional sensitivity and precision.

Specifications

Combines Flame and Transversely Heated Graphite Furnace (THGA) capabilities for exceptional sensitivity and precision.

  • Status: Active
  • Country: USA
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Over 70 elements, including Pb, Cd, Zn, Cu, and Ni
  • Signal stability, relative standard deviation : RSD <0.3% for flame measurements; <0.5% for furnace measurements
  • Atomizer types : Flame
  • Atomizer types : Hydride Generation
  • Bandwidth : User-selectable slit widths: 0.2, 0.7, and 2.0 nm
  • Wavelength range : 184–900 nm
  • Wavelength accuracy : ±0.1 nm
  • Background correction : Longitudinal Zeeman-effect background correction for furnace analyses
  • Optics type : True double-beam optics with fiber optics for enhanced detection limits
  • Burner head material : Titanium burner head, corrosion-resistant; standard 10-cm single-slot configuration
  • Gas management : Integrated gas management for both modes
  • Detection system : SSD (segmented, CMOS)
  • Monochromator : Littrow design with motorized drive for automatic wavelength selection and peaking
  • Lamp carousel : Motorized 8-lamp mount for Lumina™ hollow cathode lamps and electrodeless discharge lamps (EDLs)
  • Flame atomizer : Air/Acetylene and N₂O/Acetylene configurations with modular sample introduction system
  • Furnace atomizer : Transversely Heated Graphite Furnace (THGA)
  • Furnace vision system : Built-in TubeView color furnace camera for sample monitoring
  • Furnace heating rate/max temp : Heating rate up to 3000°C/s; max temperature 3000°C
  • Typical tube lifetime : Extended lifetime due to optimized heating profiles
  • Sensitivity (Furnace) : Cd detection limit: <0.2 pg
  • Sensitivity (Flame) : Cu detection limit: <0.004 µg/mL
  • Safety features : Comprehensive safety interlocks for both flame and furnace operations
  • Power Requirements and Consumption : 231 V, 50/60 Hz
  • Environmental requirements : Ambient temperature: +10 °C to +35 °C Relative humidity: 20 to 80% non-condensing
  • Dimensions and Weight: 95 cm (37.5 in.) 73 cm (29 in.) 68 cm (27 in.) 141 kg (311 lb)

Articles

Other company product

Avio 550 Max

  • Category: Optical Emission Spectroscopy
  • Technique: ICP-OES/ ICP-AES
  • Manufacturer: PerkinElmer
  • Country: USA
  • Available: Active
Detailed