Specifications

  • Category: Spectroscopy
  • Technique: Atomic Absorption Spectroscopy
  • Manufacturer: Hitachi High-Tech
  • Country: Japan
  • Available: Active
All specifications

About

Short description

Graphite Furnace AAS with high sensitivity, permanent Zeeman magnet, and advanced automation for trace element analysis.

Specifications

Graphite Furnace AAS with high sensitivity, permanent Zeeman magnet, and advanced automation for trace element analysis.

  • Status: Active
  • Country: Japan
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Over 70 elements, including heavy metals like Pb, Cd, Zn, Cu, and Ni
  • Signal stability, relative standard deviation : RSD ≤ 1.0% for furnace
  • Atomizer types : Furnace
  • Bandwidth : 4 steps (0.2, 0.4, 1.3, 2.6 nm)
  • Wavelength range : 190–900 nm with automatic spectral peak setting
  • Wavelength accuracy : -
  • Background correction : Polarized Zeeman method with simultaneous sample and reference beam measurement for real-time correction
  • Optics type : Double-beam method with Polarized Zeeman background correction
  • Gas management : Automatic gas flow rate setting with advanced monitoring
  • Detection system : Dual photomultiplier tubes (PMT)
  • Monochromator : Czerny-Turner design, 400 mm focal length, 1800 lines/mm grating, blazed at 200 nm
  • Lamp carousel : 8-lamp turret with automatic lamp positioning, fine adjustment, and simultaneous 2-lamp lighting capability
  • Photomultiplier : Dual PMTs for high precision in Graphite Furnace applications
  • Furnace atomizer : Transversely heated graphite furnace with twin injection technology and optional hydride generation
  • Furnace vision system : Integrated high-definition camera for real-time observation of sample injection
  • Furnace heating rate/max temp : 50–3000°C with precise temperature control
  • Typical tube lifetime : Extended graphite tube lifetime due to advanced heating design
  • Sensitivity (Furnace) : Cd detection limit: <0.2 ppb
  • Safety features : Advanced interlocks for cooling water, heating system, and gas flow monitoring; automatic shutdown on errors
  • Power Requirements and Consumption : 220–240 V, 7.5 kVA, 50/60 Hz
  • Environmental requirements : Operating temperature: 15–35°C; Humidity: 45–65%
  • Dimensions and Weight: 800 × 650 × 637 mm; 137 kg