Specifications

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Accelerator Mass Spectroscopy
  • Manufacturer: Ionplus
  • Country: Switzerland
  • Available: Active
All specifications

About

Short description

AMS system optimized for radiocarbon dating and isotope analysis. Features helium stripping for high transmission, a hybrid cesium sputter ion source, and outstanding measurement stability. Widely regarded as the standard for precision in ¹⁴C-AMS applications.

Specifications

AMS system optimized for radiocarbon dating and isotope analysis. Features helium stripping for high transmission, a hybrid cesium sputter ion source, and outstanding measurement stability. Widely regarded as the standard for precision in ¹⁴C-AMS applications.

  • Status: Active
  • Country: Switzerland
  • Isotopic: Yes
  • Type of measurable elements: Radiocarbon and cosmogenic nuclides
  • Measurable isotopes/elements: Radiocarbon (¹⁴C)
  • Analyzer type : Accelerator MS
  • Ion source type: Hybrid cesium negative sputter ion source for solid and gas samples
  • Inlet types: Solid and gas sample handling, with a 40-position random-access sample changer
  • Mass range : Optimized for radiocarbon isotopes
  • High Resolution : Yes
  • Sensitivity : High sensitivity with up to 47% helium stripping transmission
  • Abundance sensitivity : High, capable of resolving small variations in isotopic ratios
  • Detection limits : Blanks older than 50,000 radiocarbon years, with a machine blank up to 68,000 radiocarbon years
  • Precision : 0.2% or better for ¹⁴C/¹²C and ¹³C/¹²C ratios
  • Detector type : Low-noise gas ionization detector with virtually no degradation.
  • Primary beam : Negative cesium sputter beam
  • Accelerator voltage : 200 kV
  • Geometry type : Tandem geometry with vacuum-insulated accelerator terminal
  • Focusing type : Electrostatic focusing
  • Magnetic sector radius/ angle : 90° high and low energy magnetic sector with ion beam angle
  • Electric sector radius/ angle : 90° electrostatic analyzer with ±40 kV voltage
  • Cooling system : Fully air-cooled; no cooling water or SF₆ required
  • Vacuum system : Powerful high vacuum system (4 × 700 l, 3 × 300 l, 1 × 80 l Pfeiffer) and fore vacuum system
  • Gas supply: Helium stripping gas
  • Power Requirements and Consumption : 2.5 kW average power consumption
  • Dimensions and Weight: 3.2 m × 2.6 m × 2.2 m; 4,500 kg

Articles

Other company product

MILEA

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Accelerator Mass Spectroscopy
  • Manufacturer: Ionplus
  • Country: Switzerland
  • Available: Active
Detailed