Specifications

  • Category: Inductively Coupled Plasma Mass Spectrometry
  • Technique: Triple Quad ICP-MS
  • Manufacturer: Thermo Fisher Scientific
  • Country: Germany
  • Available: Discontinued
All specifications

About

Short description

Retired high-performance triple quadroupole ICP-MS with advanced interference removal for complex samples.

Specifications

Retired high-performance triple quadroupole ICP-MS with advanced interference removal for complex samples.

  • Status: Discontinued
  • Country: Germany
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Analyzer type : Tandem Quadrupole MS
  • Ion source type: Inductively Coupled Plasma
  • Mass range : Q1: 2-240 amu, Q3: 2-290 amu
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : User definable in the mass range 2-225 u Fixed resolution and Extended Sensitivity in the mass range 225-290 amu
  • Sensitivity : 7Li: 65 kcps/µg·L-1; 59Co: 150 kcps/µg·L-1; 238U: 330 kcps/µg·L-1 (SQ mode)
  • Dynamic range : Over 10 orders of magnitude
  • Detection limits : <0.5 ng·L-1 for 9Be, <0.1 ng·L-1 for 115In and 209Bi in SQ mode
  • Precision : <0.1% RSD for isotope ratio (e.g., 107Ag/109Ag)
  • Signal stability, relative standard deviation : <2.0% for 10 minutes, <3.0% for 2 hours
  • Detector type : Dual mode discrete dynode with pulse and analog detection
  • Oxides (%) : CeO/Ce <2%
  • Reaction cell system : Yes
  • Reaction cell system details: QCell with four gas controllers (He, H2, O2, NH3); supports additional gases by request
  • High Matrix Introduction system : Optional
  • Spray chamber : Baffled cyclonic, high purity quartz with Peltier cooling, -10 to +20 °C range
  • Nebulizer : Concentric glass with options for high TDS and aggressive sample compatibility
  • Peristaltic pump : 12-roller, four-channel, low pulsation with inert rollers
  • Torch : Demountable quartz torch, push-in design, self-aligning injector
  • Injector : 2.5 mm ID quartz injector, screw-in, no O-rings required
  • Interface : Ni or Pt-tipped cones, 1.1 mm sample cone, 0.5 mm skimmer cone
  • RF generator frequency : ~27 MHz
  • RF generator power : 400 W to 1600 W
  • CRC gas flow : He (up to 12 mL·min-1), H2 (up to 15 mL·min-1), O2, NH3, other gases on request
  • Dwell time : Minimum 100 µs in both pulse and analog mode
  • Cooling system : Requires external water cooling, optimal supply at 21 °C
  • Vacuum system : Three-stage differential pumping with split-flow turbo and external rotary pump
  • Gas supply: Argon, with options for additional gases depending on application requirements
  • Power Requirements and Consumption : 200-240 V AC, 50/60 Hz, single phase, 3000 VA apparent; 2200 W effective
  • Environmental requirements : Temperature: 15-35 °C, Humidity: 20-80% non-condensing
  • Dimensions and Weight: 748 mm (width) x 665 mm (depth) x 1020 mm (height)

Articles

Other company product

iCAP MTX

  • Category: Inductively Coupled Plasma Mass Spectrometry
  • Technique: Triple Quad ICP-MS
  • Manufacturer: Thermo Fisher Scientific
  • Country: Germany
  • Available: Active
Detailed