Specifications

  • Category: Inorganic and Isotopic Mass Spectrometry
  • Technique: Isotope Ratio Mass Spectrometry for Light Stable Isotopes
  • Manufacturer: Nu Instruments
  • Country: UK
  • Available: Active
All specifications

About

Short description

Ultra-high-resolution isotope ratio mass spectrometer. Capable of resolving complex isobaric interferences in methane, nitrogen, and oxygen isotopes.

Specifications

Ultra-high-resolution isotope ratio mass spectrometer. Capable of resolving complex isobaric interferences in methane, nitrogen, and oxygen isotopes.

  • Status: Active
  • Country: UK
  • Isotopic: Yes
  • Type of measurable elements: Light stable isotopes (C, N, S, O, H)
  • Measurable isotopes/elements: ¹³C/¹²C, ¹⁵N/¹⁴N, ¹⁸O/¹⁶O, ³⁴S/³²S, ²H/¹H, and more
  • Analyzer type : Magnetic Sector MS
  • Ion source type: Electron impact
  • Inlet types: Dual inlet system with 4 bellows (2 standard, 2 for extended analysis); continuous flow inlet
  • Mass range : 1–280 Dalton
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Resolving power >40,000 (5–95% edge definition)
  • Multicollector : Yes
  • Collectors qty : 9 adjustable Faraday collectors and 1 ion counter (SEM)
  • Sensitivity : High sensitivity due to 16 kV ion source and differential pumping
  • Abundance sensitivity : Excellent for resolving minor isotopologues like }13CH3​D and 12CH2​D2​
  • Detection limits : Sub-ppm detection limits
  • Precision : CH4 application : internal precision: Δ13CH3D ≤ 0.3 ‰ , Δ12CH2D2 ≤ 1.0 ‰
  • Detector type : Combination of Faraday and ion counting detectors
  • Possible amplifiers : Fully adjustable collector slits with "hot wire" technology for isotopologue studies
  • Acceleration voltage : 16 kV
  • Geometry type : ESA-Quadrupole-Magnet double-focusing geometry
  • Focusing type : True stigmatic double focusing
  • Magnetic sector radius/ angle : 800 mm radius, 85° deflection
  • Electric sector radius/ angle : 1017.6 mm radius, 72.5° deflection
  • Cooling system : Integrated air-cooled system
  • Vacuum system : Differential pumping system with 2 turbo pumps (300 L/s each) for the source and 6 ion pumps for the analyzer
  • Gas supply: Helium, nitrogen, or other gases depending on analytical requirements