Specifications

  • Category: Inductively Coupled Plasma Mass Spectrometry
  • Technique: Multicollector ICP-MS
  • Manufacturer: Nu Instruments
  • Country: UK
  • Available: Active
All specifications

About

Short description

Large-geometry, double-focusing MC-ICP-MS optimized for high-resolution isotopic and elemental analysis. Features enhanced mass dispersion (~1700 mm) for superior resolving power and flat-topped peaks.

Specifications

Large-geometry, double-focusing MC-ICP-MS optimized for high-resolution isotopic and elemental analysis. Features enhanced mass dispersion (~1700 mm) for superior resolving power and flat-topped peaks.

  • Status: Active
  • Country: UK
  • Isotopic: Yes
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Covers most elements from Li to m/z 310, including actinides and transition metals
  • Analyzer type : Magnetic Sector MS
  • Ion source type: Inductively Coupled Plasma
  • Inlet types: Laser ablation, autosamplers, and desolvation systems
  • Mass range : 3–310 amu
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Standard: >800; Peak flat at >5000 resolution; Edge resolving power: up to >30,000 (5% to 95% edge definition)
  • Multicollector : Yes
  • Collectors qty : 16 Faraday cups and up to 5 ion-counting detectors (SEM/Daly)
  • Abundance sensitivity : <0.5 ppm using deceleration filters
  • Dynamic range : >10¹²
  • Detection limits : Sub-ppq levels for specific isotopes, dependent on mode of analysis
  • Precision : Sub-ppm precision for isotopic ratio measurements
  • Signal stability, relative standard deviation : <2% over extended periods of operation
  • Detector type : Faraday cups, discrete dynode secondary electron multipliers (SEM), and Daly detectors
  • Possible amplifiers : 10¹⁰, 10¹², and 10¹³ ohm resistors, software-switchable configurations
  • Acceleration voltage : 10 kV
  • Reaction cell system : No
  • Spray chamber : Peltier-cooled cyclonic spray chamber
  • Nebulizer : Concentric nebulizer
  • Peristaltic pump : Yes, multi-channel for sample delivery and drainage
  • Torch : High-performance torch with robust construction for stability
  • Interface : Enhanced sensitivity interface with variable zoom optics for adjusting resolving power
  • RF generator frequency : 27 MHz
  • RF generator power : 2.0 kW
  • Geometry type : Nier-Johnson geometry with large dispersion
  • Focusing type : Double focusing with independently adjustable slits for high resolution
  • Magnetic sector radius/ angle : 750 mm/ 70 deg
  • Electric sector radius/ angle : 943 mm/ 70 deg
  • Cooling system : Water-cooled system for optimal thermal stability
  • Vacuum system : Fully turbo-pumped, differential pumping configuration
  • Gas supply: High-purity argon and helium for laser ablation; optional custom gases for specific systems
  • Power Requirements and Consumption : 230/400 V, 3-phase, 50/60 Hz
  • Environmental requirements : Operating temperature: 18–24°C; humidity: <60%, non-condensing