Specifications

  • Category: Inductively Coupled Plasma Mass Spectrometry
  • Technique: Multicollector ICP-MS
  • Manufacturer: Thermo Fisher Scientific
  • Country: Germany
  • Available: Discontinued
All specifications

About

Short description

Retired multicollector ICP-MS optimized for isotopic and elemental analysis.

Specifications

Retired multicollector ICP-MS optimized for isotopic and elemental analysis.

  • Status: Discontinued
  • Country: Germany
  • Isotopic: Yes
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: U, Pb, Hf, Nd, Sr, and more, including Li isotopes and actinides
  • Analyzer type : Magnetic Sector MS
  • Ion source type: Inductively Coupled Plasma
  • Inlet types: Laser ablation, gas chromatography, liquid chromatography, autosamplers
  • Mass range : 4–310 amu
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Up to 10,000
  • Multicollector : Yes
  • Collectors qty : Configurable up to 9 Faraday cups (and 8 ion counters)
  • Sensitivity : Standard: 7Li: 10 V/ppm; 208Pb: 20 V/ppm; 238U: 40 V/ppm With desolvation: 7Li: 60 V/ppm; 208Pb: 100 V/ppm; 238U: 200 V/ppm
  • Abundance sensitivity : <5 ppm for 237/238 without RPQ; <500 ppb with RPQ (transmission >90%)
  • Dynamic range : Up to 10¹²
  • Detection limits : Sub-ppq levels for specific isotopes (e.g., uranium)
  • Precision : Sub-ppm precision for isotopic ratios
  • Signal stability, relative standard deviation : <2% over one hour
  • Detector type : Faraday cups and discrete dynode electron multipliers
  • Possible amplifiers : Virtual amplifiers with selectable 10¹⁰, 10¹¹, and 10¹² ohm resistors
  • Acceleration voltage : 10 kV
  • Reaction cell system : Yes
  • Reaction cell system details: RPQ lens for isobaric interference reduction with high transmission
  • High Matrix Introduction system : Optional
  • Spray chamber : Peltier-cooled cyclonic spray chamber
  • Nebulizer : Concentric nebulizer
  • Peristaltic pump : Not explicitly mentioned
  • Torch : Torch with platinum-tipped guard electrode
  • Interface : Jet Interface with enhanced pumping capacity
  • RF generator frequency : 27.12 MHz
  • RF generator power : 1.6 kW
  • Geometry type : Nier-Johnson geometry
  • Focusing type : Double focusing with magnetic and electrostatic sectors
  • Magnetic sector radius/ angle : 230 mm/ 90 deg
  • Electric sector radius/ angle : 220 mm/ 90 deg
  • Cooling system : Water-cooled
  • Vacuum system : Fully turbo-pumped system with enhanced capacity for Jet Interface
  • Gas supply: High-purity argon and optional collision/reaction gases for RPQ lens
  • Environmental requirements : Temperature: 18–24°C; humidity: 50–60%, non-condensing
  • Dimensions and Weight: 2450х 1890х 1740, 2200 kg