Specifications

  • Category: Inductively Coupled Plasma Mass Spectrometry
  • Technique: Multicollector ICP-MS
  • Manufacturer: Thermo Fisher Scientific
  • Country: Germany
  • Available: Active
All specifications

About

Short description

Multicollector ICP-MS with MS/MS mode for removing isobaric interferences and enhancing accuracy in isotopic measurements.

Specifications

Multicollector ICP-MS with MS/MS mode for removing isobaric interferences and enhancing accuracy in isotopic measurements.

  • Status: Active
  • Country: Germany
  • Isotopic: Yes
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Rare earth elements, actinides, and transition metals
  • Analyzer type : Magnetic Sector MS
  • Analyzer type : Tandem Magnetic Sector MS
  • Ion source type: Inductively Coupled Plasma
  • Inlet types: Laser ablation, autosamplers, HPLC, GC
  • Mass range : Up to 260 amu
  • High Resolution : Yes
  • Mass resolution/ Mass resolving power : Low, medium, high, and extra high resolution (>15,000)
  • Multicollector : Yes
  • Collectors qty : 10 moveable Faraday cups and 1 central dual-mode detector (Faraday/SEM)
  • Abundance sensitivity : <50 ppb abundance sensitivity at 1 amu
  • Dynamic range : Over 9 orders of magnitude (up to 60 Gcps)
  • Detection limits : Sub-ppq levels with enhanced interference removal via MS/MS
  • Precision : High precision for isotopic and elemental ratio analysis, especially with MS/MS
  • Detector type : Faraday cups and discrete dynode electron multiplier
  • Possible amplifiers : 24 amplifier slots, 12 x 10¹¹ Ω amplifiers, 4 x 10¹³ Ω amplifiers
  • Reaction cell system : Yes
  • Reaction cell system details: MS/MS with pre-cell quadrupole filtering
  • Spray chamber : Peltier-cooled cyclonic spray chamber
  • Nebulizer : Concentric nebulizer
  • Torch : High-performance torch system
  • Interface : Jet interface optional
  • RF generator frequency : 27.12 MHz
  • Geometry type : Nier-Johnson geometry with MS/MS addition
  • Focusing type : Double focusing with additional MS/MS quadrupole focusing
  • Magnetic sector radius/ angle : Large-radius
  • Cooling system : Water-cooled
  • Vacuum system : Fully turbo-pumped
  • Gas supply: High-purity argon (>99.996%) with reactive gases (O2, N2O, NH3, SF6) and collision gases (H2, He)