Specifications

  • Category: Spectroscopy
  • Technique: Atomic Absorption Spectroscopy
  • Manufacturer: PG Instruments
  • Country: UK
  • Available: Active
All specifications

About

Short description

Dual-mode AAS combining Flame and Graphite Furnace atomizers with automated switch-over for flexible applications.

Specifications

Dual-mode AAS combining Flame and Graphite Furnace atomizers with automated switch-over for flexible applications.

  • Status: Active
  • Country: UK
  • Elemental: Yes
  • Type of measurable elements: Metals and non-metals
  • Measurable isotopes/elements: Elemental analysis including Cu, Cd, Ba, Al, Ti, Na, K, and more
  • Signal stability, relative standard deviation : RSD < 0.7% for Cu (Air/Acetylene flame) and RSD < 2.0% for Cd (Graphite Furnace)
  • Atomizer types : Flame
  • Atomizer types : Furnace
  • Bandwidth : Adjustable: 0.1, 0.2, 0.4, 1.0, 2.0 nm
  • Wavelength range : 185 to 910 nm
  • Wavelength accuracy : ±0.15 nm
  • Background correction : Deuterium Arc, Self-Reversal
  • Optics type : Czerny-Turner monochromator
  • Burner head material : Titanium alloy with Air/Acetylene, N₂O/Acetylene, and Air/LPG options
  • Gas management : Automatic gas flow control for both modes
  • Detection system : Photomultiplier tube (PMT)
  • Monochromator : Czerny-Turner configuration with high precision optics
  • Lamp carousel : Automatic 8-lamp turret
  • Photomultiplier : High-sensitivity PMT
  • Flame atomizer : 10 cm titanium burner; height and angle adjustable via software
  • Furnace atomizer : Longitudinally heated graphite furnace; maximum temperature 3000°C
  • Furnace vision system : Gas piston-controlled graphite furnace with precise alignment
  • Furnace heating rate/max temp : >3000°C with precision feedback control
  • Typical tube lifetime : Pyrolytic graphite tubes with extended lifetime; supports up to 2000 cycles
  • Sensitivity (Furnace) : Cd detection limit: < 0.4 pg
  • Sensitivity (Flame) : Cu detection limit: < 0.004 µg/mL
  • Safety features : Burner identification, flame sensor, gas leak detection, over-pressure cutoff, argon pressure monitoring
  • Power Requirements and Consumption : 200–240 VAC, 50/60 Hz
  • Environmental requirements : Temperature: 10–35°C; Humidity: 20–80% (non-condensing)
  • Dimensions and Weight: Compact benchtop design